About split cabinet hvac installation method

time2012/02/13

1, Air conditioning vents outdoor and indoor units they fit on the, the spot of indoor unit options: might be of interest when installing the console tall and scale of the channel towards the room to protect yourself from are not to be installed. Have a very good air condition and air distribution, air conditioners and make room inside of a large area is usually cold (warm) air blown to corners in the room.
Ac units far away from heat and make of harmful gases, and the might want to avoid sunshine.
Unit installation location will need to have adequate inspection and maintenance space. Within a indoor unit installation route to install for the wall, these units left in advance of a minimum of 1m, so leave as much as 0.5m, leaving the top of the around 0.3m space for air supply and air supply fan air conditioner filter maintenance devices used.
2, the indoor unit to be as close at the power source, and choose between outdoor and indoor unit where the nearest installation, it saves the pipeline.
Heavier outdoor unit is required to be set up on buildings where solid, might be relating to the balcony, the window special steel or concrete pedestal. Open place, they put in a sunshade rain cover, and ought to avoid the strong wind blowing straight unit air vents, heat affected unit out, the proper way is to wind these devices on the exhaust vent and placed at 90 degrees.
That will have plenty of outdoor unit maintenance, installation and operation of your installation space, with regards to possible leaving other buildings, now to stay away from the obstruction of air convection cooling effect.
Because cabinet air conditioning power, whenever the noise is large, now the installation location also has to choose harassment does not affect the inside without having it be close houses adjacent factors.
Indoor unit could possibly be fixed with anchor bolts with the concrete floor units. Sometimes, so as not to freshen up the land, the ac unit gets wet, or mop the land, sweeping the land board, fan coil it is in the Secretary of state for the shell scratched, dirty, can be carried out inside unit below a thickness of 60-100mm wooden base, will undoubtedly be fixed while in the base unit.
Wooden bottom of the length, width and size ought to be corresponding to or slightly bigger the bottom of the product size.
Installation, the best fixed wooden base, followed by fixed to your wooden base machine.
Considering that the indoor unit is often a slender-shaped closet, improper installation, easily forward dumping, so as the installation should take measures to avoid fall.
Before anti-dumping measures two units: one on top of these units before goods with anti-iron rectangular-shaped anchors, anchor fixed to your casing at the summit side of an plane, at right angles off and away to the other side among the wall fixed. Second, the base the gps device established in the cargo down resistant to the floor fixture. The decision concerning which method, whether visual base unit, generally take advantage of the base unit installed, used the 1st approach. Within the unit measures against goods shown in Figure 5.
Install the outdoor unit getting solid.
3, the indoor and outdoor units are fixed, the refrigerant should be related to pipes and drains. Split air conditioning cabinet back or bottom for the unit all over the place sides with the hole left channel leads could very well be selected as reported by different needs. Pipe joints set up on the chassis, hence the operation can be difficult.
Split cabinet ac unit refrigerant pipe joints, both with quick connector is related to another expertise in the flare nut fitting (flare nut fitting strategy to operation, installation of split air conditioner at the rear of the technical details within your description). That the cabinet ac pipe connection would be the using of quick connectors, their operation along with front about the dressing method can mention the practice.
Combination of cabinet air conditioning indoor plastic drain hose, with units in water tray drain port connection to the nozzle cement and wrapped having a bandage with good.
Any exposed pipes on the interior, exterior drainage pipes will be wrapped in insulation to counteract dew condensation as a result of outside air into, contributing to water dripping phenomenon.
4, the call: Connection wire cabinet ac often takes self, and also its connection method varies randomly different. Therefore, within your specific wiring operation, what strict accordance with product instructions, wire leads in the unit when in any window over apron with dedicated wiring insulation holes, central air conditioner quite a few wires that can be used tighten clamp unit and a soft belt wrap fixed.
Into your above safety and correct by a test, you might conduct an effort run.