1, Cabinet air conditioner indoor and outdoor units are placed on the floor, near the indoor unit options: In addition to height and measurement room to offset the channel installation may be of interest, can not be installed. Have a great air conditioning and air distribution, exchange units, the large area of ??the room, often cold (warm) air to blow all corners of the room.
AC beyond the unit of heat and harmful gases, another really want to avoid direct sunlight.
The installation location of the unit, there will be adequate inspection and maintenance space. The installation path of the indoor unit installed directly to the wall, including about one meter left opposite, so leave a minimum of 0.5 meters, remain in any case, the gas supply and the supply fan air-conditioning filter maintenance equipment used in the 0.3 m space at the top.
2, the indoor unit to choose between close to the power supply, indoor and outdoor units, recently installed, it saves the pipeline.
Heavier outdoor units can be found in the solid, can be placed around the balcony, the window of special steel or concrete base of the building. Open place, they should create a shade Covers must pun intended, strong wind and direct units vents, the heat-affected unit, intake and exhaust ports in the right way the wind, and placed in 90 degrees.
That allows you to plenty of outdoor machine repair, install and run these installation space, as far as possible from the other buildings, and to prevent obstruction of the air convection cooling effect.
Cabinet the power of AC devices, the noise is large, the results of the installation location also needs to never enviromentally friendly harassment does not affect the housing adjacent factors.
The indoor unit is likely to be fixed with anchor bolts to the concrete floor units. Sometimes, washing surfaces, including wet or mopping the floor, sweeping the land board, within the shell scratched, dirty part, around the wooden base units in the following thickness of 60-100mm is feasible, through the base unit, may be fixed.
The wooden bottom of the length, width and size, will be the bottom of the numbers or slightly larger than the device size.
Installation, initial fixed wooden base, fixed wooden base machine.
Indoor unit, mainly because this is really a slender-shaped wardrobe, improper installation, it is easy to move dumping, the installation should take measures to stop the decline.
Two units of the anti-dumping measures: air conditioning vents, one to raise the front of units of goods and antiferroelectric rectangular anchor, anchor you start your aircraft shell side, fan coil at right angles and close the fixed wall of sleep problems. Second, the time limit for these devices things on the floor fixture, up and down around the cargo. Specific personal choice of which method, whether it is the basic unit of visual, generally use the basic unit of installation, use the first method. In addition to the unit measures the goods shown in Figure 5.
Install the outdoor unit of the solid.
3, indoor and outdoor unit is fixed, the refrigerant supply piping and drains. Often choose should be noted that the split AC unit cabinet back or bottom of the units right and left and right sides of the hole left channel cues. Fittings installed in the chassis, so the operation is very difficult.
Split the cabinet air conditioning unit refrigerant pipe fittings, quick connector and another experience cone nut connector (the operation of the cone nut accessories source, technical details are described in which the rear installed split air conditioning units). Cabinet air conditioning units connected by a pipe case, the consumption of quick connector, its operation, and the method of your dress, can concentrate on the practice of
The scope of the cabinet air-conditioning equipment can have a good indoor plastic drains, water dish, drain the nozzle cement port link units, and wrapped in bandages.
Any exposed pipes in the internal, external drainage pipes are wrapped in insulation no condensation, and the entry of outside air, causing the dripping phenomenon.
4, Call: Connect the air conditioning of the line cabinets can take the self, smoke damper, the connection method is random variation. Therefore, the specific operation of wiring, internal strict accordance with product instructions, lead apron through a dedicated wiring insulation Kong next window, air conditioning vents some wire and created to tighten the use of clamp units and fixed soft packaging from the unit.
Throughout the above security and test its fit, you can try to run.