About split cabinet air conditioner installation method
1, Fan coil indoor and outdoor units are placed and incapacitated, the spot of indoor unit options: should be thought about when installing the condominium high and height and width of the channel within the room to hide from can't installed. Have a great air condition and air distribution, air conditioning units as well as to make room inside a large area may cold (warm) air blown to each corners using the room.
Air conditioning units outside of heat and set of harmful gases, additionally the wish to avoid sunlight.
Unit installation location ought to have adequate inspection and maintenance space. Inside indoor unit installation technique to install onto the wall, machine left opposite no less than 1m, so leave at a minimum 0.5m, leaving the top of the definitely 0.3m space for air supply and air supply fan air filter maintenance devices used.
2, the indoor unit to generally be as near towards energy, and judge between outdoor and indoor unit where nearest installation, it saves the pipeline.
Heavier outdoor unit really need to be running on buildings where solid, can be placed over a balcony, of the question special steel or concrete pedestal. Open place, really are a must build a sunshade rain cover, and must stay away from the strong wind blowing straight unit air vents, heat affected unit out, the right way is to wind the system about the exhaust vent and placed at 90 degrees.
To be able to have enough outdoor unit maintenance, installation and operation of the installation space, when it comes to possible faraway from other buildings, and in order to pun intended, the obstruction of air convection cooling effect.
Because cabinet hvac power, whenever the noise is big, consequently the installation location should also glance at the harassment does not affect the medial and towards the houses adjacent factors.
Indoor unit might be fixed with anchor bolts to concrete floor units. Sometimes, so as not to cleanse the ground, the ac unit gets wet, or mop the surface, sweeping the earth board, below the Secretary of state for the shell scratched, dirty, is feasible contained in the unit below a thickness of 60-100mm wooden base, are going to be fixed contained in the base unit.
Wooden base of the length, width and size can be equal to or slightly bigger the bottom of includes a size.
Installation, most important fixed wooden base, after fixed for the wooden base machine.
Due to the fact indoor unit may be a slender-shaped closet, improper installation, easily forward dumping, so the installation should take measures in order to prevent fall.
Before anti-dumping measures two units: one appears these products prior to an goods with anti-iron rectangular-shaped anchors, anchor fixed in the casing at the summit side belonging to the plane, at right angles to the other side of this wall fixed. Second, reduced includes a set up in the cargo down with floor fixture. The group of which method, whether visual base unit, generally use any base unit installed, used the initial approach. Around the unit measures against goods shown in Figure 5.
Install the outdoor unit to be solid.
3, the outdoor and indoor units are fixed, the refrigerant could possibly be attached to pipes and drains. Split air conditioner cabinet back or bottom of this unit right and left sides of an hole left channel leads may be selected determined by different needs. Pipe joints the thing that the chassis, in order that the operation can be difficult.
Split cabinet ac unit refrigerant pipe joints, both with quick connector is connected to another contact the flare nut fitting (flare nut fitting method of operation, setting up split air conditioning in the back of the technical details with the description). If for example your cabinet air conditioning equipment pipe. air conditioning vents connection will probably be the for example quick connectors, their operation and also in front in the dressing method can infer the practice.
Couple of cabinet air conditioning units indoor plastic drain hose, with units in the water tray drain port link with the nozzle cement and wrapped utilizing bandage with good.
Any exposed pipes through the interior, exterior drainage pipes should really be covered with insulation to quit dew condensation because of the outer layer air into, resulting in water dripping phenomenon.
4, the Connection: Connection wire cabinet ac unit normally takes self, as well as its connection method varies randomly different. Therefore, in your specific wiring operation, installed in strict accordance with product instructions, wire leads of your unit when inside of a window over apron with dedicated wiring insulation holes, several wires to produce tighten clamp tool and a soft belt wrap fixed.
Towards above safety and correct by the test, you can still smoke fire damper conduct an endeavor run.