Fan coil of the main uses and market supply and demand

time2012/02/02

About Split cabinet air conditioner installation method
1, Fan coil indoor and outdoor units are placed on the floor, the vicinity of indoor unit options: might be of interest when installing in addition to tall and measurements of the channel through the room to counteract can't be installed. Have a great air condition and air distribution, ac units to make room using a large area tend to be cold (warm) air blown everybody corners on the room.
Ac units beyond heat and of harmful gases, additionally the really have to avoid direct sunlight.
Unit installation location will have adequate inspection and maintenance space. Throughout the indoor unit installation route to install directly into wall, includes a left opposite approximately 1m, so leave at minimum 0.5m, leaving the top of the in any case 0.3m space for air supply and air supply fan air conditioning filter maintenance devices used.
2, the indoor unit getting as near on the power source, and choose between outdoor and indoor unit when the nearest installation, it saves the pipeline.
Heavier outdoor unit should be can be found in buildings where solid, can be placed about the balcony, the window special steel or concrete pedestal. Open place, they ought to establish a sunshade rain cover, and must pun intended, the strong wind blowing straight unit air vents, heat affected unit out, the right way would be wind it into your exhaust vent and placed at 90 degrees.
That allows you to plenty of outdoor unit maintenance, installation and operation of these installation space, as far as possible away from the other buildings, and then prevent the obstruction of air convection cooling effect.
Because cabinet ac unit power, when the noise is big, as a result installation location also needs to becoming enviromentally friendly harassment does not affect within and never outside of the houses adjacent factors.
Indoor unit may very well be fixed with anchor bolts into the concrete floor units. Sometimes, so as not to wash the surface, includes a gets wet, or mop the ground, sweeping the land board, inside the Ministry of the shell scratched, dirty, is workable around the unit below a thickness of 60-100mm wooden base, will likely be fixed through the base unit.
Wooden bottom of the length, width and size will be figure to or slightly larger than the bottom of these devices size.
Installation, the initial fixed wooden base, after fixed for that wooden base machine.
Mainly because the indoor unit s really a slender-shaped closet, improper installation, easily forward dumping, consequently the installation should take measures to end fall.
Before anti-dumping measures two units: air conditioning vents one presents itself the unit ahead of goods with anti-iron rectangular-shaped anchors, anchor fixed into your casing beginning side of your plane, at right angles away and off to sleep issues for the wall fixed. Second, time frame these devices the thing that the cargo down around the floor fixture. Specific personal choice of which method, whether visual base unit, generally utilize base unit installed, used the very first approach. Along the unit measures against goods shown in Figure 5.
Install the outdoor unit being solid.
3, the indoor and outdoor units are fixed, the refrigerant will be powering pipes and drains. Split ac unit cabinet back or bottom associated with the unit right and left sides about the hole left channel leads are usually selected as stated by different needs. Pipe joints installed in the chassis, therefore operation can be difficult.
Split cabinet air conditioning unit refrigerant pipe joints, both with quick connector is associated with another experience the flare nut fitting (flare nut fitting source of operation, installing split air conditioning unit at the rear of the technical details inside description). In case the cabinet ac unit pipe connection may possibly be the consumption of quick connectors, their operation as well front of your dressing method can focus on the practice.
Range of cabinet air conditioning equipment can indoor plastic drain hose, with units in water tray drain port link with the nozzle cement and wrapped getting a bandage with good.
Any exposed pipes through the interior, exterior drainage pipes is required to be wrapped in insulation to not have dew condensation because of the outer air into, triggering water dripping phenomenon.
4, the call: connection wire cabinet air conditioning can take self, smoke fire damper and its connection method varies randomly different. Therefore, within specific wiring operation, inside the middle of strict accordance with product instructions, wire leads from unit when the next window over apron with dedicated wiring insulation holes, some wires to create use of tighten clamp unit and a soft belt wrap fixed.
Throughout the above safety and proper by its test, you can conduct an attempt run.