1, indoor and outdoor units are placed on the ground, the location of indoor unit options: fan coil should be considered when
installing the unit in height and size of the channel into the room to avoid can not be installed. Have a good air condition
and air distribution, air conditioners and to make room in a large area can be cold (warm) air blown to all corners of the
room.
Air conditioners away from heat and place of harmful gases, and the need to avoid direct sunlight.
Unit installation location should have adequate inspection and maintenance space. In the indoor unit installation method to
install into the wall, the unit left in front of at least 1m, so leave at least 0.5m, leaving the top of at least 0.3m space
for air supply and air supply fan air filter maintenance devices used.
2, the indoor unit to be as close to the power supply, and choose between indoor and outdoor unit where the nearest
installation, it saves the pipeline.
Heavier outdoor unit should be installed in buildings where solid, can be placed on the balcony, the window special steel or
concrete pedestal. Open place, they should set up a sunshade rain cover, and should avoid the strong wind blowing straight
unit air vents, heat affected unit out, the correct way is to wind the unit to the exhaust vent and placed at 90 degrees.
In order to have enough outdoor unit maintenance, installation and operation of the installation space, as far as possible
away from other buildings, and to prevent the obstruction of air convection cooling effect.
Because cabinet air conditioner power, for when the noise is large, so the installation location should also consider the
harassment does not affect the interior and not near the houses adjacent factors.
Indoor unit can be fixed with anchor bolts to the concrete floor units. Sometimes, in order not to wash the ground, the unit
gets wet, or mop the floor, sweeping the floor board, under the Ministry of the shell scratched, dirty, can be done in the
unit below a thickness of 60-100mm wooden base, will be fixed in the base unit.
Wooden base of the length, width and size should be equal to or slightly larger than the bottom of the unit size.
Installation, the first fixed wooden base, and then fixed to the wooden base machine.
As the indoor unit is a slender-shaped closet, improper installation, easily forward dumping, so the installation should take
measures to prevent fall.
Before anti-dumping measures two units: one at the top of the unit before the goods with anti-iron rectangular-shaped
anchors, anchor fixed to the casing at the top side of the plane, at right angles off to the other side of the wall fixed.
Second, the lower the unit installed in the cargo down against the floor fixture. The specific choice of which method,
whether visual base unit, generally use the base unit installed, auto air conditioning vents used the first approach. Down the unit measures against
goods shown in Figure 5.
Install the outdoor unit to be solid.
3, the indoor and outdoor units are fixed, the refrigerant can be connected to pipes and drains. Split air conditioner
cabinet back or bottom of the unit left and right sides of the hole left channel leads can be selected according to different
needs. Pipe joints installed in the chassis, so the operation is not easy.
Split cabinet air conditioner refrigerant pipe joints, both with quick connector is connected to another connection with the
flare nut fitting (flare nut fitting method of operation, installation of split air conditioner in the back of the technical
details in the description). If the cabinet air conditioner pipe connection is the use of quick connectors, their operation
and in front of the dressing method can refer to the practice.
Group of cabinet air conditioners indoor plastic drain hose, with units in the water tray drain port connection to the nozzle
cement and wrapped with a bandage with good.
Any exposed pipes in the interior, exterior drainage pipes should be wrapped in insulation to prevent dew condensation caused
by the outside air into, resulting in water dripping phenomenon.
4, the Connection: Connection wire cabinet air conditioner usually takes self, and its connection method varies randomly
different. Therefore, in the specific wiring operation, installed in strict accordance with product instructions, wire leads
from the unit when within a window over apron with dedicated wiring insulation holes, a few wires to use tighten clamp device
and a soft belt wrap fixed.
Into the above safety and correct by the test, you can conduct a trial run central air conditioner .